Reports until 17:05, Monday 06 November 2017
H1 IOO (IOO)
cheryl.vorvick@LIGO.ORG - posted 17:05, Monday 06 November 2017 - last comment - 18:29, Monday 06 November 2017(39305)
IO, as of Monday, Nov. 6th

Today:

Tomorrow:

- Cheryl JeffK, JeffB, PeterK

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 17:16, Monday 06 November 2017 (39307)
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 18:29, Monday 06 November 2017 (39309)AOS, INS, IOO, ISC, SYS, VE
On The IM4 Cage Baffle Assembly D1002745
This aLOG is merely to provide data on the troublesome IM4 baffle assembly such that it might be improved in some vent in the future.

As one may recall, in order to adjust the pitch alignment of the IMs / HAUX / HAM Auxiliary suspensions, one must remove their cage protection baffle. Recall that each of the IMs have their individualized cage protection baffle,
    Optic   Former    Baffle
            Name      Drawing / Assembly
    IM1     SM1       D0902378
    IM2     PMMT1     D0902380
    IM3     PMMT2     D0902382
    IM4     SM2       D1002745
where IM1's baffle has a large opening, IM2 and 3's are (from what I can tell) identical, and IM4 has much larger coverage, and has a special insert D1002722 in order to provide further protection for the suspension wires against stray IFO REFL beams during lock loss.

It is this special insert that gives us the most trouble when taking the IM4 baffle assembly on and off, because it does not clear the suspension cage's front (HR-side) earthquake stop brackets (D1000539, D1000540, D1002360, D1002361) when they're secure. One needs to loosen bolts and back off these EQ stop brackets to remove this baffle.

Attached are several pictures:
(1) & (2) show the baffle assembly after removal from the IM4 cage
(3) show the drawing numbers for each baffle part
(4) shows the metal erosion at the baffle's contact points with the EQ stop brackets
(5) shows IM4 after the baffle has been removed, highlighting the EQ stop brackets
(6) & (7) show the particulate that erodes off of the baffle every time we remove & re-install it.

The pains experienced during removal and re-install of this baffle assembly are not new. Kiwamu and I had trouble in the last vent when we were mechanically relieving the alignment sliders (see the bottom of LHO aLOG 12811) and during original install by Cheryl and Deepak (see 5633)

LLO aLOG 3814 seem to imply that something was done chamber-side to L1 IM4 to make the baffles fit better.
Images attached to this comment