Reports until 08:17, Tuesday 07 November 2017
H1 SEI
hugh.radkins@LIGO.ORG - posted 08:17, Tuesday 07 November 2017 - last comment - 10:59, Tuesday 07 November 2017(39310)
WHAM4 ISI Balanced and left Unlocked with soft covers held away from table

I'll detail the rebalancing after I review the previous payload to document changes--Exec Summ: removed many kgs.

Comments related to this report
hugh.radkins@LIGO.ORG - 09:12, Tuesday 07 November 2017 (39312)

My tabulation of the payload results in a reduction of balance masses by 11.75Kgs.

hugh.radkins@LIGO.ORG - 10:59, Tuesday 07 November 2017 (39316)

Just wanted to outline my process for balancing the ISI:

1) With ISI still locked, reset RX RY target to LOCATIONMON value (cartesian LIGO global), set Z target to locked position plus 20um.

2) Unlocked ISI and balanced to get RESIDUALMON pretty close to zero so that locking was easy.

3) Relocked and unlocked a few times looking for repeatability.

4) Reset the RX RY and Z targets to new locked position.  It is not unexpected for the locked position to change like this after lots of work on the table.  These changed -46urad, +11urad, +0.7um for RX RY and Z.

5) unlocked and fine tuned the balance.

6) Relocked and consolidated and secured all masses. Unlock to lock change: RX -7.4urad, RY +0.6urad, Z -19um.

7) Updated SDF for RX RY and Z Target, e.g., H1:ISI-HAM4_CPS_RX_TARGET w/ Z set less the 20um for in air buoyancy effect.

FWIW--Locking the ISI at this balance condition was easy, unlike unlocking it when it was 11kg heavy.  Lightest weight balance item is ~50grams.