Reports until 10:59, Wednesday 08 November 2017
H1 SEI
jim.warner@LIGO.ORG - posted 10:59, Wednesday 08 November 2017 (39338)
Monthly seismometer centering FAMIS 6092

All the STSs are okay. Corner station ISIs are in air. ETMY is somewhat out of spec, though.

2017-11-08 10:52:36.354536
All STSs prrof masses that within healthy range (< 2.0 [V]). Great!


Here's a list of how they're doing just in case you care:
STS A DOF X/U = -0.718 [V]
STS A DOF Y/V = 0.064 [V]
STS A DOF Z/W = -0.195 [V]
STS B DOF X/U = 0.388 [V]
STS B DOF Y/V = 0.944 [V]
STS B DOF Z/W = -0.609 [V]
STS C DOF X/U = 0.368 [V]
STS C DOF Y/V = -0.065 [V]
STS C DOF Z/W = 0.938 [V]
STS EX DOF X/U = -0.164 [V]
STS EX DOF Y/V = 0.47 [V]
STS EX DOF Z/W = 0.151 [V]
STS EY DOF X/U = 0.144 [V]
STS EY DOF Y/V = 0.169 [V]
STS EY DOF Z/W = 0.51 [V]


Assessment complete.
 

 

Averaging Mass Centering channels for 10 [sec] ...
2017-11-08 10:52:39.355680


There are 17 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.327 [V]
ETMX T240 2 DOF Y/V = -0.574 [V]
ETMY T240 3 DOF Z/W = 0.347 [V]
ITMX T240 1 DOF X/U = -0.418 [V]
ITMX T240 1 DOF Z/W = -0.337 [V]
ITMX T240 2 DOF Y/V = -0.37 [V]
ITMX T240 3 DOF X/U = -0.652 [V]
ITMY T240 1 DOF X/U = -0.386 [V]
ITMY T240 1 DOF Z/W = -0.549 [V]
ITMY T240 2 DOF Z/W = -0.654 [V]
ITMY T240 3 DOF X/U = -1.001 [V]
ITMY T240 3 DOF Y/V = -0.389 [V]
ITMY T240 3 DOF Z/W = -0.604 [V]
BS T240 1 DOF Z/W = -0.564 [V]
BS T240 2 DOF Y/V = -0.491 [V]
BS T240 3 DOF X/U = -0.683 [V]
BS T240 3 DOF Z/W = -0.469 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = 0.296 [V]
ETMX T240 1 DOF Y/V = 0.19 [V]
ETMX T240 1 DOF Z/W = 0.222 [V]
ETMX T240 2 DOF Z/W = 0.125 [V]
ETMX T240 3 DOF X/U = 0.171 [V]
ETMX T240 3 DOF Y/V = 0.284 [V]
ETMX T240 3 DOF Z/W = 0.223 [V]
ETMY T240 1 DOF X/U = -0.003 [V]
ETMY T240 1 DOF Y/V = 0.109 [V]
ETMY T240 1 DOF Z/W = -0.123 [V]
ETMY T240 2 DOF X/U = 0.201 [V]
ETMY T240 2 DOF Y/V = -0.161 [V]
ETMY T240 2 DOF Z/W = 0.0 [V]
ETMY T240 3 DOF X/U = -0.132 [V]
ETMY T240 3 DOF Y/V = -0.004 [V]
ITMX T240 1 DOF Y/V = -0.046 [V]
ITMX T240 2 DOF X/U = -0.106 [V]
ITMX T240 2 DOF Z/W = -0.093 [V]
ITMX T240 3 DOF Y/V = -0.047 [V]
ITMX T240 3 DOF Z/W = 0.016 [V]
ITMY T240 1 DOF Y/V = -0.178 [V]
ITMY T240 2 DOF X/U = 0.263 [V]
ITMY T240 2 DOF Y/V = -0.239 [V]
BS T240 1 DOF X/U = 0.131 [V]
BS T240 1 DOF Y/V = -0.262 [V]
BS T240 2 DOF X/U = -0.041 [V]
BS T240 2 DOF Z/W = 0.032 [V]
BS T240 3 DOF Y/V = -0.024 [V]


Assessment complete.