PSL weekly status

Not sure how relevant this is right now.

 

Laser Status:
SysStat is good
Front End Power is 35.66W (should be around 30 W)
HPO Output Power is 154.0W
Front End Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 0 days, 0 hr 27 minutes (should be days/weeks)
Reflected power = 26.11Watts
Transmitted power = 50.55Watts
PowerSum = 76.66Watts.

FSS:
It has been locked for 0 days 0 hr and 27 min (should be days/weeks)
TPD[V] = 2.491V (min 0.9V)

ISS:
The diffracted power is around 0.71% (should be 3-5%)
Last saturation event was 0 days 0 hours and 26 minutes ago (should be days/w

Possible Issues:
PMC reflected power is high
ISS diffracted power is Low