Reports until 13:28, Wednesday 22 August 2012
H2 CDS
david.barker@LIGO.ORG - posted 13:28, Wednesday 22 August 2012 - last comment - 15:04, Wednesday 22 August 2012(3934)
EY front ends restarted, new h2tcsetmy model installed

We had a timing glitch at EY which required a restart of all EY front ends. I took the opportunity to install the new h2tcsetmy model for the ring heater.

I did a manual burt restore of the safe.snap files and found problems with

I'll fix the ones marked *

Comments related to this report
bram.slagmolen@LIGO.ORG - 15:04, Wednesday 22 August 2012 (3941)

I restored ISCEY, ETMY and TMSY to 3am, 22 August 2012.