This morning I relieved the PR3 of the mechanical rubbing Kissel pointed out in 39384. The Front HR Upper Right stop was grounded on the face of the optic. I also freed up the locked down PR2. We'll run some TFs at lunch when IO is finished with the MC bypass install, but before alignment through the PR chain.
At lunch I took the needed TFs. Both suspensions look healthy now according to the 6 DOF TFs (each) which can be found in the usual spot at:
and