Reports until 14:29, Monday 20 November 2017
H1 PSL
jeffrey.bartlett@LIGO.ORG - posted 14:29, Monday 20 November 2017 (39489)
Weekly PSL Status

Laser Status:
SysStat is good
Front End Power is 35.8W (should be around 30 W)
HPO Output Power is 151.5W
Front End Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 2 days, 7 hr 43 minutes (should be days/weeks)
Reflected power = 25.37Watts
Transmitted power = 48.21Watts
PowerSum = 73.58Watts.

FSS:
It has been locked for 2 days 7 hr and 43 min (should be days/weeks)
TPD[V] = 2.039V (min 0.9V)

ISS:
The diffracted power is around 1.6% (should be 3-5%)
Last saturation event was 2 days 7 hours and 43 minutes ago (should be days/weeks)

Possible Issues:
PMC reflected power is high
ISS diffracted power is Low