Reports until 13:13, Wednesday 22 November 2017
H1 SUS
travis.sadecki@LIGO.ORG - posted 13:13, Wednesday 22 November 2017 (39509)
SR2 SUS structure dog clamps torqued

The dog clamps securing SR2 to HAM4 have been torqued to 8.5 ft/lbs (as close to 100 in/lbs (E1100411) as our torque wrench would allow) except for those on the north side of the structure.  The heads of the screws for the dog clamps on the north side are so close to the structure that the head of the torque wrench would not fit.  I attempted to duplicate the torque on these dog clamps by testing the already torqued dog clamps on the other sides of the structure and doing my best to replicate the force required to produce the torque using a normal flex handle socket wrench.  Upcoming B&K measurements of this structure will tell if I did well.