WP 7222
FRS 4559
Modified HWS camera mounts to isolate grounding per T1600449 and D1200566.
1. HWS camera positions were marked before disconnecting
2. Kapton tape was used between camera and base
3. A nylon screw was used to hold both together
4. Camera was tested for isolation to table without any cables connected. Power cable was modified per D1200566.
5. HWS breakout chassis and Polarization PD whitening chassis were isolated from table with kapton tape
Camera tested good (isolated ) with no cables connected.
F. Clara, T. Shaffer