High power oscillator diode box current adjustment(s) [FAMIS 8449]
With the ISS off, the diode box currents were adjusted. A screen dump of the laser main screen is attached.
| Diode Box [#] |
Old [A] |
New [A] |
| 1 |
52.3 |
53.0 |
| 2 |
54.5 |
54.8 |
| 3 |
54.5 |
54.8 |
| 4 |
54.5 |
54.8 |
Another largish increase, just like last week. Not surprising really given that the diodes are near their end of life.
The power, with the ISS on, went from ~153 W to ~155 W.
This completes FAMIS task
8449
Power watchdog reset [FAMIS 3920]
Both the front end and oscillator power watchdogs were reset at 18:24 UTC (10:24 local). This completes FAMIS task
3920.