Reports until 08:56, Monday 04 December 2017
H1 AOS
betsy.weaver@LIGO.ORG - posted 08:56, Monday 04 December 2017 (39615)
HWS paths checked in red last week, late entry

Earlier last week when we were using the red eye safe alignment laser to align the elliptical baffles in BSC2, I also checked and tweaked the HWS paths on HAM4.  Reasons for doing this were that

1) I moved the 4" HWSX steering mirror a few weeks ago in order to install the scraper baffle and slide the SRM cage back 5mm

2) We bumped a 2" steering mirror on the HWSY path (the one most central to the table)

Indeed, we found both paths slightly misaligned - both beams made it through the last lens out the VPs, but were off center.  I tweaked only the mirrors above, knowing that those were the ones with issues.

I verified that the beam is well centered into the HWSX scraper baffle which was upgraded a few weeks ago.  I also did a quick check that the beam is ~well centered going through the HWSY scraper baffle.

I made Aidan aware that I was doing this.