corey.gray@LIGO.ORG - posted 10:34, Monday 04 December 2017 (39621)
PSL Weekly Report (FAMIS #7467)

NOTE:  PMC reflected power is note as being high....this has been noted atleast for the last 1-2 months (I only looked that far back).  So just wanted to make a note of that.  Closing FAMIS task 7467).

Laser Status:
SysStat is good
Front End Power is 35.74W (should be around 30 W)
HPO Output Power is 154.4W
Front End Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 0 days, 14 hr 22 minutes (should be days/weeks)
Reflected power = 23.59Watts
Transmitted power = 48.95Watts
PowerSum = 72.55Watts.

FSS:
It has been locked for 0 days 14 hr and 22 min (should be days/weeks)
TPD[V] = 1.62V (min 0.9V)

ISS:
The diffracted power is around 2.6% (should be 3-5%)
Last saturation event was 0 days 14 hours and 21 minutes ago (should be days/weeks)

Possible Issues:
PMC reflected power is high

 