A quick table summary of the alignment of the newly installed baffles that have apertures.
Suspension | Alignment Method | Accuracy |
---|---|---|
HAM2 | ||
MC1 | Aligned with the beam during overall alignment. | 2-3mm to center |
MC3 | Aligned with the beam during overall alignment. | 2-3mm to center |
PR3 | Aligned by sight and checked by IO team with paper target. | ~4mm |
PRM | Used the acrylic target and then later checked okay with the beam. | 2-3mm to center |
HAM3 | ||
MC2 | Aligned with the beam during overall alignment. | ~5mm to center |
PR2 | Aligned with the beam during overall alignment. | ~5mm to center |
HAM4 | ||
SR2 | Aligned with the beam during overall alignment. | ~5mm to center |
HAM5 | ||
SR3 | Aligned by sight and checked with beam. | ~4mm to center |
SRM HR | Aligned with beam. | 2-3mm to center |
SRM AR | Aligned with beam. | ~1mm to center |
BSC1 | ||
ITMY Elliptical | Aligned using provided target. | ~5mm |
BSC2 | ||
BS HR & AR Elliptical | Aligned using provided target. | 1mm |
BSC3 | ||
ITMX Elliptical | Aligned using provided target. | ~5mm |
*All other newly installed baffles with any type of adjustment were aligned by sight.