Displaying report 1-1 of 1.
Reports until 16:06, Friday 08 December 2017
H1 SEI
hugh.radkins@LIGO.ORG - posted 16:06, Friday 08 December 2017 (39698)
WHAM5 ISI Final scan and Unlocked

Looks clean.  Unlocked ISI and left with covers pulled out so TFs can be run.  Have updated the positions for isolation and committed (HAMs 3 & 4 as well to svn:

hugh.radkins@zotws9:burtfiles 0$ svn st -u
        *    10241   ISI_ETMY.hughdonotmonitor~
        *    10241   ISI_ITMX.hughdonotmonitor~
        *    10241   ISI_ITMY.hughdonotmonitor~
M            15862   h1isiham4_OBSERVE.snap
M            16444   h1isiham3_safe.snap
M            16444   h1isiham4_safe.snap
M            16444   h1isiham5_safe.snap
M            15862   h1isiham3_OBSERVE.snap
M            15862   h1isiham5_OBSERVE.snap
Status against revision:  16483
hugh.radkins@zotws9:burtfiles 0$ svn commit -m "Update snaps for CPS control DC Position" *.snap
Sending        h1isiham3_OBSERVE.snap
Sending        h1isiham3_safe.snap
Sending        h1isiham4_OBSERVE.snap
Sending        h1isiham4_safe.snap
Sending        h1isiham5_OBSERVE.snap
Sending        h1isiham5_safe.snap
Transmitting file data ......
Committed revision 16484.
hugh.radkins@zotws9:burtfiles 0$ pwd
/opt/rtcds/userapps/release/isi/h1/burtfiles
hugh.radkins@zotws9:burtfiles 0$

Displaying report 1-1 of 1.