Displaying report 1-1 of 1.
Reports until 17:32, Friday 08 December 2017
H1 IOO (IOO, SEI, SUS)
cheryl.vorvick@LIGO.ORG - posted 17:32, Friday 08 December 2017 - last comment - 10:37, Tuesday 12 December 2017(39702)
HAM2 vacuumed and wiped - IMs are still moving around, 4 more bolts to tighten

Vacuumed in HAM2, using this combination of vaccum hoses:

The Kapton tube was class-A, so I used it to vacuum horizontal surfaces in MC3, MC1, PR3, IM1, and IM3 cages, and I did use it in contact with the metal.

I kept close track of the space under the +Y MC3 blade spring, and from this test area I can see that larger particulate are picked up by the vacuum, but smaller particulate are not, and when I wipe with a IPA wipe, the small particulate are removed.  Picture attached.

I put IM1 on EQ stops and used the vacuum to remove a large particle on the upper portion of the face of IM1, and this was successful without any contact between the optic and the Kapton tube.

I used the same technique to remove large particulate from the MC REFL periscope 2 lower mirror, which was very contaminated.  Not all of the particulate that I could see would come off of the optic, so some may be scratches that have been present since install.

Given my conclusion that vacuuming leaves small particulate, I wiped over all of the surfaces that I could reach in HAM2 from both the West and East doors.

PRM stage M2 has OSEM flags on the HR side of the tower that do not go into OSEMS, and the -Y flag has shifted out of place, and will need to be restored.

The really big story is that IM1, IM2, and IM3 shifted in alignment between 50 and 1500urad, and I have only one explanation for this, which is that the 4 8/32 bolts that hold the top plate to the side plates are loose, and will need to be tightened.

These bolts are covered by the brackets that hold the blade spring EQ stops at the top of the tower, so the brackets will need to come off to give access to the remaining 4 loose bolts.

This also reveals that the root cause of the shift I saw in IM3 after the B&K, a shift  I recreated myself by tapping with a dog clamp on the top plate, are these 4 hidden loose bolts.

Comments related to this report
cheryl.vorvick@LIGO.ORG - 17:36, Friday 08 December 2017 (39704)
Images attached to this comment
cheryl.vorvick@LIGO.ORG - 23:11, Saturday 09 December 2017 (39708)

IMAGES FROM HAM2:

  • black glass behind MC REFL Periscope 2 top mirror
    • as found - lots of particulate
    • after vacuuming (using a Kappton tube that was in contact with the glass (non-optical surface))
Images attached to this comment
cheryl.vorvick@LIGO.ORG - 23:25, Saturday 09 December 2017 (39709)

IMAGES FROM HAM2:

  • MC3 +Y blade spring attachment point, under the blade spring
    • first image: as found - lots of particulate, many sizes, large and small
    • second image: after vacuuming (using a Kappton tube that was in contact with the metal) and wiping with an IPA wipe
      • in this image the front area under the blade spring has been wiped, and no particulate is visible
      • the back area under the blade spring has only been vacuumed, and many small particles remain
      • there is a clear line between the area that was only vacuumed and the area that was wiped
      • from this I conclude that if the goal is to remove all sizes of particulate, wiping appears to be the best method
Images attached to this comment
cheryl.vorvick@LIGO.ORG - 23:40, Saturday 09 December 2017 (39710)

IMAGES FROM HAM2:

  • MC3 and PRM cages
    • PRM cage, top plate - large area with landmarks (blade springs)
    • PRM cage, top plate - same image, zoomed in to a fiber
    • MC3 cage - large image with landmarks
    • MC3 cage - same image, zoomed in to the fibers that form what looks like the letter X
Images attached to this comment
cheryl.vorvick@LIGO.ORG - 23:49, Saturday 09 December 2017 (39711)

IMAGES FROM HAM2:

  • vacuum set up
    • class-A Kappton tube installed on the tubing
    • the tubing installed on the tubing/vacuum hose adaptor, and the vacuum hose covered in C3
    • the vacuum setup from the class-A Kappton tube to the vacuum canister
Images attached to this comment
cheryl.vorvick@LIGO.ORG - 00:41, Monday 11 December 2017 (39715)

IM loose bolts, and what needs to be removed to fix:

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 10:37, Tuesday 12 December 2017 (39732)
Opened FRS Ticket 9573.

Note, however -- while we agree that alignment pins in the cage (as suggested in the FRS) would do well to remove the slop described -- after further investigation Cheryl found much more success in relieving the pitch adjustment screws and re-engaging them on IM3. The guess is that they had been over stressed, warping both the top plate under discussion among other things. Not a solid case, but IM3 cage / OSEMs no longer moves / move when you look at it wrong.
Displaying report 1-1 of 1.