Displaying report 1-1 of 1.
Reports until 15:39, Thursday 14 December 2017
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 15:39, Thursday 14 December 2017 (39769)
SR3 and SRM SUS Look Free of Rubbing After Doors ON (Not Yet Pumped Down, of Course)
J. Kissel, B. Weaver

Betsy and I took standard top-to-top mass transfer functions of H1 SUS SRM and H1 SUS SR3 to ensure after the heat of first contact removal and door re-application they're still free. They are. Great!

Results attached.
(Suspensions are undamped, with alignment offsets ON)

Data and updated processing scripts have been committed to the repo.
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Data/
    2017-12-14_1729_H1SUSSRM_M1_WhiteNoise_L_0p01to50Hz.xml
    2017-12-14_1729_H1SUSSRM_M1_WhiteNoise_P_0p01to50Hz.xml
    2017-12-14_1729_H1SUSSRM_M1_WhiteNoise_R_0p01to50Hz.xml
    2017-12-14_1729_H1SUSSRM_M1_WhiteNoise_T_0p01to50Hz.xml
    2017-12-14_1729_H1SUSSRM_M1_WhiteNoise_V_0p01to50Hz.xml
    2017-12-14_1729_H1SUSSRM_M1_WhiteNoise_Y_0p01to50Hz.xml

/ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Data
    2017-12-14_1743_H1SUSSR3_M1_WhiteNoise_L_0p01to50Hz.xml
    2017-12-14_1743_H1SUSSR3_M1_WhiteNoise_P_0p01to50Hz.xml
    2017-12-14_1743_H1SUSSR3_M1_WhiteNoise_R_0p01to50Hz.xml
    2017-12-14_1743_H1SUSSR3_M1_WhiteNoise_T_0p01to50Hz.xml
    2017-12-14_1743_H1SUSSR3_M1_WhiteNoise_V_0p01to50Hz.xml
    2017-12-14_1743_H1SUSSR3_M1_WhiteNoise_Y_0p01to50Hz.xml