ISI Coil Driver BSC2 Corner3

It seems that when the modifications were done to this particular chassis, there was an accidental swapping of wire harnesses when reassembling that was causing the team som difficulty. The swap I found was at the ISI Coil Driver Chassis Interface Board, connectors P6 and P9, which would swap the Coarse/Fine 1 & 2 Coil Driver Output signals. The unit was reinstalled and I'm waiting to hear the results of this correction.

Comments related to this report
edmond.merilh@LIGO.ORG - 09:18, Wednesday 20 December 2017 (39837)

Upon testing, Jim reported that the issue was resolved by this action.