jonathan.hanks@LIGO.ORG - posted 10:04, Friday 22 December 2017 - last comment - 10:21, Friday 22 December 2017(39888)
Restarted h1lsc0 models
I restarted the h1lsc0 models at about 18:00 UTC.

All of the non-IOP models showed a FE failure and DAQ failure.  All of the corresponding models that do IPC with the h1lsc0 models are showing IPC errors (as expected).

When I looked on the front end the models were loaded and the epics processes where running.

I issued a /etc/stop_models.sh and /etc/start_models.sh.
Comments related to this report
corey.gray@LIGO.ORG - 10:17, Friday 22 December 2017 (39890)

I cleared the IPC errors on all front ends connected to the LSC by hitting the DIAG RESET on them.  Now we are all GREEN.

jonathan.hanks@LIGO.ORG - 10:21, Friday 22 December 2017 (39891)
I've attached some of the kernel logs (via dmesg).