Displaying report 1-1 of 1.
Reports until 10:27, Thursday 04 January 2018
H1 SEI (SEI)
corey.gray@LIGO.ORG - posted 10:27, Thursday 04 January 2018 (39983)
SEI Seismometer Mass Check (FAMIS#6094)

Ran the checks for the STS & T240 masses (& will close FAMIS #6094).

STSs:  Fine & within range (same as last month). 

T240s: Now ETMy* HEPI is on its stops in prep for EY vent, and with that said, had the following masses out of range:

Averaging Mass Centering channels for 10 [sec] ...
2018-01-04 10:17:17.353721

There are 13 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 1 DOF X/U = 0.42 [V]
ETMX T240 1 DOF Z/W = 0.396 [V]
ETMX T240 2 DOF X/U = -0.445 [V]
ETMX T240 2 DOF Y/V = -0.88 [V]
ETMX T240 3 DOF X/U = 0.318 [V]
ETMX T240 3 DOF Y/V = 0.435 [V]
ETMX T240 3 DOF Z/W = 0.327 [V]
* ETMY T240 3 DOF Z/W = 0.413 [V]
ITMX T240 1 DOF X/U = -0.412 [V]
ITMX T240 2 DOF Z/W = 0.33 [V]
ITMX T240 3 DOF X/U = -0.438 [V]
ITMY T240 3 DOF X/U = -0.648 [V]
ITMY T240 3 DOF Z/W = -1.08 [V]

Displaying report 1-1 of 1.