HAM4 / HAM5 / BSC2 SR and BS SUS Are Free of Rubbing at ~1e-6 Torr
J. Kissel

I've taken standard rubbing-check, top-mass to top-mass transfer functions for all suspensions in HAM4, HAM5, and BSC2 now that we're down to about 1e-6 Torr (which is sufficient a vacuum that the suspension positions won't change further from buoyancy). Good news: All suspensions are free of rubbing after pumpdown, including SRM, SR2, SR3 and BS

Data files are listed below. Detailed results will be processed and posted in due time.
    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SR?/SAGM1/Data/2018-01-04*.xml

    /ligo/svncommon/SusSVN/sus/trunk/HLTS/H1/SR3/SAGM1/Data/2018-01-04*.xml

    /ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BS/SAGM1/Data/2018-01-04*.xml

As a teaser / proof, I attach screenshots of each M1 Pitch to M1 Pitch transfer functions for the Triples.
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:52, Thursday 04 January 2018 (39998)
J. Kissel

Detailed transfer function analysis of SR3. Everything looks fabulous -- no complaints!
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 15:07, Thursday 04 January 2018 (40000)
J. Kissel

Detailed analysis of the beam splitter's transfer functions also show no problems. Free and clear!
Non-image files attached to this comment