Displaying report 1-1 of 1.
Reports until 00:53, Saturday 06 January 2018
H1 PSL (IOO)
cheryl.vorvick@LIGO.ORG - posted 00:53, Saturday 06 January 2018 - last comment - 16:38, Monday 08 January 2018(40022)
flashing IMC, then no light

I was mproving the flashing in the IMC, and then something happened, and there was no light into the IMC.

I collected 14 seconds of data on channels I think might help an expert explain, and have attached the plots.

NPRO is running, and OSC_PD_AMP_DC_OUT shows 35W, so that part of the laser in on.

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 01:12, Saturday 06 January 2018 (40023)

Called Peter, he'll take a look tomorrow.

jason.oberling@LIGO.ORG - 16:38, Monday 08 January 2018 (40040)

Filed FRS 9692 for this trip.

Displaying report 1-1 of 1.