WP7273: Add whitening filters to h1sqz model
Daniel, Dave:
new h1sqz model was started.
New corner station Beckhoff Slow Controls code
Daniel, Sheila, Dave:
New Beckhoff code for h1ecatc1plc[1,3,4] was installed. The resulting new DAQ INI files and target autoBurt.req files were installed.
DAQ Restart
DAQ was restarted to assimilate the new INI files from the above work.
Timing
Daniel:
The h1ecatc1plc1 EPICS settings were not fully restored after yesterday's code changes, this resulted in a RED timing system. Daniel fixed this issue today.
h1isietmy pending filter module change
Jim, Dave:
Jim's latest filter file for h1isietmy was loaded to green up the overview.
Stuck SUS ITMX, ITMY excitations
Jeff K, Dave:
Stuck excitations and testpoints were cleared on h1susitm[x,y]
BTW: Timing system is currently RED. Daniel is testing a comparator on the 16th port (port number 15) of the first fan-out in the CER.