Reports until 16:50, Wednesday 10 January 2018
H1 CDS (SQZ)
david.barker@LIGO.ORG - posted 16:50, Wednesday 10 January 2018 (40089)
created an SDF for Squeezer Beckhoff Slow Controls

WP7278

Daniel, Sheila, Dave:

By following Jonathan's wiki instructions, I have created an SDF for the new Squeezer Beckhoff Slow Controls (h1ecatc1plc4). I used the next available DCU_ID and CPU_ID (1036 and 13 respectively). The system was built and started on h1build.

I have added the system to the SDF Overview MEDM. It is configured to use its safe.snap reference, which was created by listing all the non-readonly channels in the h1ecatc1plc4 autoBurt.req file. As a starting point, all channels are being monitored by SDF.

This work-permit will remain open until the next DAQ restart, at which point the new SDF channels will be trended (H1EDCU_SDF.ini already has the additional channels added).

I am seeing some channel in the difference list with vanishingly small differences (e.g. 6.7e-21), I'll work with Jonathan on resolving these. Difference list is attached.

Images attached to this report