Following up on alog 40014 with reported issues on MO and RO signal chain. Looked at possible grounding issues. Tested cable SUS_ITMY-8 at satellite box and found pin 2 shorted to chamber ground. To eliminate the air-side cable, we tested directly at the feedthru. Same results, pin 2 shorted to ground. The AA/AI/Coil driver driver electronics were also power cycled.