Displaying report 1-1 of 1.
Reports until 21:15, Wednesday 17 January 2018
H1 ISC
jenne.driggers@LIGO.ORG - posted 21:15, Wednesday 17 January 2018 - last comment - 21:51, Wednesday 17 January 2018(40162)
Beam aligned to ITMX, ITMX aligned.

[Sheila, TVo, Jenne]

Today was an exercise in trying to get PRX aligned, so that we trusted our input beam and were on our way to being ready to align the HAM6 table.  So far, we think that we have the beam aligned to ITMX, and that ITMX is aligned well enough to retroreflect the beam.  We have not, however, been able to see flashes for PRX.  We are seeing fringing on the REFL camera, and on REFL_RF9_I.  Hoooray!  (This is a little bit stream-of-consciousness...we were definitely totally absolutely going home several hours ago)

Plan for going forward:

Note from Cheryl:  There is some scattered light somewhere near the output of the Faraday.  She has a photo looking in one of the viewports, and it's clear that there's light in places where we don't want light.  Her suggestion was that perhaps the input beam is too close to a mirror near the output of the Faraday, and we're clipping.  Her proposed check was moving IM1 to see if that scattered light glow (as seen on the PRM camera view that she set up) changed.  Moving by a few thousand counts on IM1 didn't change the PRM camera image, so I'm not sure that it's the Faraday or the input beam we're having a problem with.  We'll continue checking on this in parallel with the main alignment work.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 21:48, Wednesday 17 January 2018 (40164)
  • Just kidding. We got excited and aligned BS and ITMY.  Screenshot attached with PRY fringes (ITMX slider values correct, but the optic is misaligned via guardian).  PRY_and_PRX_fringes.png
  • We misaligned PRM and aligned both the ITMs, and saw nice MICH fringes.  I think that we could lock to the POP LSC PD if we felt like it.   See MICH_fringes.png
  • Restoring PRM, we see that we're getting flashes on LSC_POP_A_LF.  We need to check the alignment of ISCT1 so that we can use the sideband buildups for triggering.

We don't have analog cameras for POP, SR2.  They might be unplugged?  And I guess we need some CDS help to get the BS camera back.  It would be helpful for alignment if we could have those all working tomorrow.

Images attached to this comment
thomas.vo@LIGO.ORG - 21:51, Wednesday 17 January 2018 (40165)

Note to ourselves: Tomorrow we will try to do SRY alignment to get down to HAM6.

Displaying report 1-1 of 1.