ISCT6 Detector calibration

Daniel, Sheila, Nutsinee

Nominal laser output power measured (with a PDA100A) as 18 mW through a 98% beam splitter (Rp 98%). Transimpedance=1500 Ohms, responsivity=.221A/W (variable gain setting on PDA100A set to 0dB).

Green output power measured (with a PDA100A) as 2 mW through 95% beam splitter (~100mW IR -> 40mW green). Transimpedance=1500 Ohms, responsivity=.313A/W (variable gain setting on PDA100A set to 0dB).

NewFocus 1611 detector to lock laser to PSL: Beat frequency signal measured with spectrum analyser ~ -14dBm at 155MHz as measured from the -1dB coupled output on the TTFSS pre-amp. Note there is a signal decrease by around 5dB with large (squeezing) laser frequency shifts (~500MHz or more) that seems to be due to beam pointing errors on the 1611 detector. However locking signal depends on phase and is largely insensitive to amplitude fluctuations so we should be ok. Responsivity=.75A/W, Transimpedance=-10k Ohm, gain setting 0, Voltage = -1.6V.

Power to 1611 detector: .30mW from PSL + .67mW from sqz laser -> .49mW on detector after 50/50 beam-splitter. MEDM screen reads .21mW ?? If the transimpedance is adjusted to -5k Ohm MEDM screen reads correct, but I suspect something is still odd about this

Fibre (PSL) power rejected = 1.3 uW measured with a PD1A detector (2 K impedance).

Fibre (PSL) power launched = 27 uW measured with a PD1A detector from a 10% beam splitter. Disabled gain selection setting (alog 40161) has been corrected. Note the beamsplitter was changed from 2% transmission in the original drawing (BS8) to 10% transmission.

Comments related to this report
nutsinee.kijbunchoo@LIGO.ORG - 13:44, Thursday 08 February 2018 (40466)

I calibrated three more PDs today. Both are Thorlabs SM1PD1A. Assuming a transimpedance of 2kOhms.

CLF Rejected PD: measured 4mW through a PBS cube. Responsivity = 4.1 A/W

Seed Launch PD: measured 9uW through a 98:2 BS. Responsivity = 4 A/W.

LO Launch PD: So little light gets through the 95:5 beam splitter so I measured the power before the beam splitter, take 5 percent of that and calibrate the PD accprdingly. The measured power (before BS10) was 85um. 5% of that is about 4um. I added 30dB gain to the detector and set the responsivity to 0.07 A/W to match what it's supposed to read. 

The only photodiode left to calibrate is the CLF Launch PD.

nutsinee.kijbunchoo@LIGO.ORG - 12:30, Tuesday 20 February 2018 (40610)

CLF launch PD calibrated last week before the table was craned. Power transmitted was 44.4mW. Responsivity = 0.4 A/W. 

Correction to the above comment, CLF Rejected and Seed Launch PD have resposivity of 0.41 and 0.4 A/W respectively.