Displaying report 1-1 of 1.
Reports until 05:05, Friday 19 January 2018
H1 PSL
peter.king@LIGO.ORG - posted 05:05, Friday 19 January 2018 (40188)
Diode box 1 current increased
Increased the diode current for DB1 from 60A to 63.5A and adjusted the temperature of diode 3.  Laser power went from ~152 W to
~187 W as reported on the Beckhoff screen.
Images attached to this report