In Friday, Travis finished cleaning up the ETMY PUM horns by filing them to the proper length and then cleaning up the debris in the flats. I then thoroughly cleaned the lower main structure using a tiger vacuum and wipes. Gerardo aided us in weighing the new ETM test mass (ETM16) and installing it in the structure using the ergo arm.
Jason also worked on setting up IAS equipment to look at the suspension in the afternoon. His equipment is parked in the far side of the weld cleanroom away from the man-door entrance into the VEA and he has caution tape around some of it. Please limit activities around this equipment and watch your step near it if you need to get to the other side. We anticipate the equipment to be removed after next week.
We are in good shape to start the fiber welding process on this suspension next week.