PSL Weekly FAMIS 7474

Laser Status:
SysStat is good
Front End Power is 35.34W (should be around 30 W)
HPO Output Power is 140.9W
Front End Watch is GRE
HPO Watch is GREEN

PMC:
It has been locked 3 days, 23 h/weeks)
Reflected power = 28.09Watts
Transmitted power = 38.88Watts
PowerSum = 66.97Watts.

FSS:
It has been locked for 3 days 21 TPD[V] = 1.627V (min 0.9V)

ISS:
The diffracted power is around 2.8% (s
Last saturation event was 3 days 21o (should be days/weeks)

Possible Issues:
PMC reflected power is high