ETMY PenRe reworked

In order to compensate for the missing mass of the new holey AERM optic being installed in the ETMY suspension, I had to rework the PenRe mass to be heavier.  SYS had designed a heavier new set of parts to swap, and I'll report that the rebuild went smoothly - the weigh compensation was pretty spot on and the install of the parts which we have had fit troubles with in the past, went in easy (thanks to Eddie's tweak on the design based on my feedback).

For the record, the weights of these masses are as follows.  Note, the idea is to make the old PenRe mass plus the old ERM mass weight equal the total of the new sets, such that the suspension hangs in the same vertical position as before.

OLD ETM01 mass 25,993g NEW AERM07 14,873g
OLD PenRe mass 53,236g NEW PenRe mass 64,356g
Total 79,229g   79,229g

Assembly weighs of the new PenRe:

  OLD PenRe New PenRe
Keeping Same Main Body 29,857g 29,857g
Keeping Same batch of small parts 3,002g 3,002g
Keeping Same wire clamp assys 168g 168g
Cans and Plates (new and old species) 19,087g 30,284g
Addable mass assys, to make total weight 1,122g 1,045g
Total from above 53,236g 64,356g

 

Comments related to this report
betsy.weaver@LIGO.ORG - 16:01, Wednesday 07 February 2018 (40460)

Doh - Typo, the ETMY AERM is AERM06, not 07.

The difference in weight between these 2 is a negligable 8g however.

Displaying report 1-1 of 1.