Reports until 12:32, Friday 26 January 2018
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 12:32, Friday 26 January 2018 - last comment - 08:39, Saturday 27 January 2018(40292)
ETMY Welding Pics
J. Kissel, for A. Bell, T. Sadecki, and D. Sellers

While on my way to and from B&K hammering the EY PCAL periscope, I snapped a few publicity photos of Angus, Travis, and Danny who were fine-tuning the alignment and measuring violin modes of the brand new fibers of newly suspended H1 SUS ETMY.

Thanks and keep up the good work, gents!
Images attached to this report
Comments related to this report
angus.bell@LIGO.ORG - 08:39, Saturday 27 January 2018 (40300)
The violin modes were remeasured (with 0.25 Hz accuracy)
position  (Hz)    fibre S/N
+X/+Y	504.5	S1400157
-X/+Y	503.0	S1400159
+X/-Y	513.25	S1800486
-X/-Y	510.5	S1800491

as these will shift after in-chamber alignment, we didn't go for higher accuracy. The  laser we used was quite noisy and should be replaced before using the kit again.