PSL Weekly FAMIS 7475
Laser Status:
SysStat is good
Front End Power is 35.24W (should be around 30 W)
HPO Output Power is 140.2W
Front End Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 0 days, 3 hr 16 minutes (should be days/weeks)
Reflected power = 23.22Watts
Transmitted power = 41.32Watts
PowerSum = 64.54Watts.

FSS:
It has been locked for 0 days 3 hr and 16 min (should be days/weeks)
TPD[V] = 1.968V (min 0.9V)

ISS:
The diffracted power is around 3.9% (should be 3-5%)
Last saturation event was 0 days 3 hours and 12 minutes ago (should be days/weeks)

Possible Issues:
PMC reflected power is high