Reports until 17:21, Tuesday 30 January 2018
LHO VE
chandra.romel@LIGO.ORG - posted 17:21, Tuesday 30 January 2018 - last comment - 15:05, Wednesday 11 April 2018(40339)
IP4 installed

[Mark D, Tyler G, Bubba G, Kyle R. Gerardo M. Chandra R]

Team effort today installing, leak checking, and activating ion pump #4. Mark, Tyler, and Bubba installed the pump this morning (thanks, guys!) and then Kyle and Gerardo leak checked with calibrated leak detector. We found a small (1.9 Torr-L/s) He leak at the 8" CFF (from factory bake?). I tightened the fasteners and made leak significantly worse (e-8 range), but then Kyle improved it with some muscle. We're calling it good at 1.1e-9 Torr-L/s He and turned high voltages on. Current was high to start (23 mA), but coming down with time.

Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 15:05, Wednesday 11 April 2018 (41386)

I'm sure I meant to write 1.9e-9 Torr-L/s laugh