AS WFS45 code changes installed on h1asc0 and h1lsc0

WP7227

Daniel, Sheila, Dave:

New models for h1asc, h1ascimc, h1lsc and h1omc were installed. DAQ was restarted.

Comments related to this report
david.barker@LIGO.ORG - 12:20, Friday 02 February 2018 (40386)

DAQ changes are shown in attached text files.

Non-image files attached to this comment
david.barker@LIGO.ORG - 13:11, Friday 02 February 2018 (40388)

there was a problem in h1ascimc.mdl with the bus-selector for the ADC inputs to the top-named ASC part. This was fixed and the h1ascimc model was restarted at 13:08PST