ALS laser End X

We shifted the ALS laser in the X end stations by ~18.6GHz (-6.2V on the crystal temperature control voltage) to bring it close to the PSL. This offset was then relieved using the front panel potentiometer. The ALS autolocker is working again.

The same shift will have to be applied to the Y end laser.

Some other strangeness:

Comments related to this report
keita.kawabe@LIGO.ORG - 11:01, Saturday 03 February 2018 (40401)

The beat note had 8MHz sidebands (attached). Shouldn't be a big problem but I don't remember seeing this before.

 