PSL Weekly Report (FAMIS #7476)

NOTE:  PSL in middle of being downgraded to frontend 35W operations for this week....next week PSL upgrade work begins.
Laser Status:
SysStat is good
Front End Power is 34.93W (should be around 30 W)
HPO Output Power is 4.592W
Front End Watch is RED
HPO Watch is RED

PMC:
It has been locked 0 days, 0 hr 0 minutes (should be days/weeks)
Reflected power = 24.46Watts
Transmitted power = 0.2101Watts
PowerSum = 24.67Watts.

FSS:
It has been locked for 0 days 0 hr and 0 min (should be days/weeks)
TPD[V] = 0.08654V (min 0.9V)

ISS:
The diffracted power is around 2.4% (should be 3-5%)
Last saturation event was 0 days 0 hours and 24 minutes ago (should be days/weeks)

Possible Issues:
PMC reflected power is high
FSS TPD is low