Reports until 10:26, Monday 05 February 2018
LHO VE
chandra.romel@LIGO.ORG - posted 10:26, Monday 05 February 2018 - last comment - 08:46, Tuesday 06 February 2018(40410)
valved in corner IPs & RGA; valved out MTPs

Valved in vertex RGA and all six main ion pumps and valved out all three main turbo pumps (all pumps reading ~1 mA). Tomorrow will open GV 5,7 for x-arm commissioning (8am-8pm local).

Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 10:51, Monday 05 February 2018 (40411)

RGA scan with IPs valved in and MTPs valved out. Also attached scan pre-vent for comparison.

Non-image files attached to this comment
kyle.ryan@LIGO.ORG - 17:25, Monday 05 February 2018 (40424)
How long had the filament been energized before taking today's scan? 
chandra.romel@LIGO.ORG - 18:13, Monday 05 February 2018 (40426)

< 90 min. Jeff K. turned filament on for me via phone instructions. Will scan again tomorrow morning before opening up to beam tube.

chandra.romel@LIGO.ORG - 08:46, Tuesday 06 February 2018 (40431)

Here is a scan after the IPs were pumping over night and turbos valved out, and RGA filament turned on for > 12 hrs.

Images attached to this comment