Displaying report 1-1 of 1.
Reports until 12:18, Monday 05 February 2018
H1 ISC
keita.kawabe@LIGO.ORG - posted 12:18, Monday 05 February 2018 - last comment - 12:18, Monday 05 February 2018(40415)
ALS X PLL was relocked after PSL work

Disabled PLL auto locker, reset the temperature feedback ("Crystal Frequency (MHz)" in the ALS_CUST_PLL screen) to zero, enabled auto locker, and it just worked.

Right now the temperature feedback is small (about 17-18MHz).

Comments related to this report
keita.kawabe@LIGO.ORG - 12:18, Monday 05 February 2018 (40416)

H1:ALS-C_FIBR_EXTERNAL_DC_NORMALIZED is about 0.8, which is somewhat smaller than before (1.1-ish on Friday) but not much and it's still good.