With the arm cavity locked I tried to measure again the WFS sensing matrix. It still looks almost degenerate in both PIT and YAW.
These are the measurements:
sensP =
1.0e-03 *
-0.2374 0.2929
-0.1506 0.1611
sensY =
1.0e-03 *
0.0133 -0.1897
0.0177 -0.2023
And these are inverted matrices:
iP =
1.0e+04 *
2.7373 -4.9782
2.5596 -4.0341
iY =
1.0e+05 *
-2.9772 2.7915
-0.2610 0.1953
The measuremetns are at about 4 Hz.
They look quite bad. I won't even try to impelment them.