ETMX OpLev Centering

This afternoon I centered the OpLev LASER at EX. The optic was misaligned upon my arrival. It was aligned for the procedure and remains that way. The sum out is currently at 18.5K counts. The attached trends show the decline of that number down from the the mid-40Ks as a step function about the end of last June. Upon consulting with Jeff K and Jason, no attempt will be made to increase this number and it should remain "usable" for the next couple of months.

Images attached to this report
Comments related to this report
edmond.merilh@LIGO.ORG - 15:46, Thursday 15 February 2018 (40560)

FYI: This trend was 1 year.