chandra.romel@LIGO.ORG - posted 17:00, Thursday 15 February 2018 - last comment - 19:58, Thursday 15 February 2018(40561)
CP4 pressure alarm settings changed

Pressure keeps rising in CP4 (PT-245B). I've asked Dave B. to raise the alarm set point one order of magnitude to 5e-4 Torr. I'm staying late again and Kyle is on stand-by to come on site later to babysit pumps, if needed. 

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 17:03, Thursday 15 February 2018 (40563)

alarms were reconfigured and restarted. Here is the difference:

-<Channel name="H0:VAC-MY_Y4_PT245B_PRESS_TORR" low="1.0e-10" high="5.0e-05" description="VE gauge, MY CP4, CC">
+<Channel name="H0:VAC-MY_Y4_PT245B_PRESS_TORR" low="1.0e-10" high="5.0e-04" description="VE gauge, MY CP4, CC">

 

chandra.romel@LIGO.ORG - 19:54, Thursday 15 February 2018 (40566)

Weird pressure curve at CP4. Eight hour trend attached. Tried to scan with RGA but pressure is too high for filament to stay on.

Images attached to this comment
chandra.romel@LIGO.ORG - 19:58, Thursday 15 February 2018 (40567)

Adjacent pressure trends

Images attached to this comment