The performance of the noise eater was last measured on the 11th October, 2017 in this alog entry. The performance is much better now. Yesterday Jason re-aligned the EOM to the beam. The output of the monitoring photodiode is now ~1.13V compared to the ~0.21V from before. The output power of the NPRO was measured to be 1.743 +/- 0.003 W in front of the EOM. Measured with an Ophir 7Z02692 power meter (S/N 805795) with a 10s average. Attached is the power noise spectrum of the NPRO output. There's quite a broad peak from ~100 Hz to ~500 Hz. I do not recall seeing this in an NPRO's output before. Not sure what it's due to at this point in time.