ETMy preliminary closeout TFs

The full set of TFs for the newly re-assembled ETMy has been taken, and all appears to be healthy and ready to be passed to the next teams that need to use it for in-chamber work.  This is the first set of TFs of the reaction chain with the new AERM, so some of the peaks in the R0 TFs have shifted due to the new mass distribution of the chain (AERM is lighter than the old ERM and the PenRe has been made heavier to compensate).  Kissel had a quick look at some of these TFs and agreed that the peak shifting seems reasonable, but noted that the dynamical model for these SUSes will need to be updated.

The TFs can be found in the usual place:

Main chain:  /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGM0/Data/2018-02-18_2037_H1SUSETMY_M0_Mono_WhiteNoise_*_tf.txt

Reaction chain: /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGR0/Data/2018-02-18_2117_H1SUSETMY_R0_WhiteNoise_*_tf.txt

I attach a reaction chain Yaw TF screenshot as a sample of the peak shifting due to the AERM.