Displaying report 1-1 of 1.
Reports until 12:53, Wednesday 21 February 2018
H1 CDS
david.barker@LIGO.ORG - posted 12:53, Wednesday 21 February 2018 - last comment - 13:14, Wednesday 21 February 2018(40638)
ETMY Hardware Watchdog Tripped on LED fault condition

This is just a FYI for future re-enabling of BSC10 ISI, the EY HWWD tripped after an LED fault persisted for more than 20 minutes. The fault condition has subsequently been removed, however the ISI trip is latched (ISI coil drivers are powered down) until such time the front panel reset button on the HWWD chassis is pressed.

Comments related to this report
david.barker@LIGO.ORG - 13:14, Wednesday 21 February 2018 (40639)

I've added more detail to the HWWD section of the CDS Overview MEDM (see attached). Each HWWD status color bar now has two elements. The left element turns RED if either PD or LED fault condition is active. The right element turns RED if the ISI system is tripped.

The left element can transition between RED and GREEN if the faults come and go. If the right element is RED, it can only be made GREEN by pressing the RESET button on the chassis itself.

I've also included a related display button to open the HWWD MEDM directly. Note that macro substitution rules requires the SITEMAP to be reopened for the button to work.

Images attached to this comment
Displaying report 1-1 of 1.