Reports until 17:42, Wednesday 21 February 2018
H1 ISC (AOS, ISC, SUS)
keita.kawabe@LIGO.ORG - posted 17:42, Wednesday 21 February 2018 (40652)
Still no retroreflection from ETMY. Kapton washers for Picos were installed. (Georgia, Keita)

We went in the EY chamber and saw that the return beam was off on the secondary mirror at 1:30 position, the radial distance from the forward going beam was maybe 5 or 6mm. The return beam was not even hitting the bottom periscope mirror under the TMS optics table.

We steered TMS suspension as much as we could using the bias slider and it was clear that we need at least twice the range for YAW, more for PIT. We need positive PIT and YAW, both at around a milliradian. That's huge misalignment.

This cannot be ring ERM as the original ERM was wedge-less.

The wedge of the new ETM is somewhat different (old one was 0.076 deg, new one 0.07, the difference is 0.006 deg or 100 urad), and this is not large enough to cause milliradian difference.

We checked apparent interference but we couldn't do a thorough job.