H1 SUS
giacomo.ciani@LIGO.ORG - posted 08:39, Tuesday 04 September 2012 - last comment - 09:36, Tuesday 04 September 2012(4067)
H1 MC1 Offsets/Gains reset for production electronics

They were changed from the settings determined on the staging building test stand (first number) to:

 

H1:SUS-MC1_M1_OSEMINF_T1_OFFSET (-12980) -12987  GAIN (1.156) 1.155

H1:SUS-MC1_M1_OSEMINF_T2_OFFSET (-14639) -14642  GAIN (1.025) 1.024

H1:SUS-MC1_M1_OSEMINF_T3_OFFSET (-13929) -13821  GAIN (1.077) 1.085

H1:SUS-MC1_M1_OSEMINF_LF_OFFSET (-13879) -13761  GAIN (1.081) 1.090

H1:SUS-MC1_M1_OSEMINF_RT_OFFSET (-12265) -12104  GAIN (1.223) 1.240

H1:SUS-MC1_M1_OSEMINF_SD_OFFSET (-12570) -12666  GAIN (1.193) 1.184

 

I will run TFs next with the Top BOSEMs and then plug in the lower AOSEMs to set their offsets/gains.