Reports until 15:14, Tuesday 04 September 2012
H2 SUS
jeffrey.garcia@LIGO.ORG - posted 15:14, Tuesday 04 September 2012 - last comment - 12:47, Wednesday 05 September 2012(4071)
SUS QUAD L1, L2 CoilOutF filter module updates
Modifications to the QUAD L1 (UIM) and L2 (PUM) stage CoilOutF filter banks were made via Foton to reflect the latest State Machine Diagrams updated last week.

The changes were saved to the filter text files, and filter coefficients were loaded via the "*_GDS_TP" medm.

The Foton filter text files were committed locally to the "cds_user_apps" Repository checked out under:
'/opt/rtcds/userapps/release/sus/h2/filterfiles/H2SUS*TMY.txt'

Comments related to this report
jeffrey.garcia@LIGO.ORG - 15:22, Tuesday 04 September 2012 (4076)
For each of the four L2 (PUM) stage Coil Output Filter banks, the differences in the Foton text file are as follows:

Previously (before 08/31/2012):

################################################################################
### ITMY_L2_COILOUTF_LL                                                      ###
################################################################################
# DESIGN   ITMY_L2_COILOUTF_LL 0 zpk([129.973],[13],1,"n")
# DESIGN   ITMY_L2_COILOUTF_LL 1 zpk([99.9877],[1],1,"n")
# DESIGN   ITMY_L2_COILOUTF_LL 2 zpk([5;19.9999],[0.5;249.809],1,"n")
# DESIGN   ITMY_L2_COILOUTF_LL 5 zpk([13],[129.973],1,"n")
# DESIGN   ITMY_L2_COILOUTF_LL 6 zpk([1],[99.9877],1,"n")
# DESIGN   ITMY_L2_COILOUTF_LL 7 zpk([0.5;249.809],[5;19.9999],1,"n")
###                                                                          ###
ITMY_L2_COILOUTF_LL 0 21 1      0      0 SimAcqOffL2        0.1022381444281  -0.9950269485578308   0.0000000000000000  -0.9513581602053965   0.0000000000000000
ITMY_L2_COILOUTF_LL 1 21 1      0      0 SimAcqOnL2    0.01018979855460631  -0.9996165783185160   0.0000000000000000  -0.9623720057438665   0.0000000000000000
ITMY_L2_COILOUTF_LL 2 21 1      0      0 SimLPL2         1.198428225279573  -1.9083200482101859   0.9083375891754886  -1.9904437581736589   0.9904583948159983
ITMY_L2_COILOUTF_LL 5 21 1      0      0 AntiAcqOffL2      9.781085186882086  -0.9513581602053965   0.0000000000000000  -0.9950269485578308   0.0000000000000000
ITMY_L2_COILOUTF_LL 6 21 1      0      0 AntiAcqOnL2      98.13736695981576  -0.9623720057438665   0.0000000000000000  -0.9996165783185160   0.0000000000000000
ITMY_L2_COILOUTF_LL 7 21 1      0      0 AntiLPL2       0.8344262751043912  -1.9904437581736589   0.9904583948159983  -1.9083200482101859   0.9083375891754886
################################################################################

Currently (as of 09/04/2012):

################################################################################
### ITMY_L2_COILOUTF_LL                                                      ###
################################################################################
# DESIGN   ITMY_L2_COILOUTF_LL 0 zpk([12],[110],1,"n")
# DESIGN   ITMY_L2_COILOUTF_LL 1 zpk([1.35],[80.5],1,"n")
# DESIGN   ITMY_L2_COILOUTF_LL 2 zpk([6;20],[0.5;250],1,"n")
# DESIGN   ITMY_L2_COILOUTF_LL 5 zpk([110],[12],1,"n")
# DESIGN   ITMY_L2_COILOUTF_LL 6 zpk([80.5],[1.35],1,"n")
# DESIGN   ITMY_L2_COILOUTF_LL 7 zpk([0.5;250],[6;20],1,"n")
###                                                                          ###
ITMY_L2_COILOUTF_LL 0 21 1      0      0 SimAcqOffL2      8.999262730598492  -0.9586809127066087   0.0000000000000000  -0.9954086141798147   0.0000000000000000
ITMY_L2_COILOUTF_LL 1 21 1      0      0 SimAcqOnL2      58.74299131244113  -0.9695955355155262   0.0000000000000000  -0.9994824154540793   0.0000000000000000
ITMY_L2_COILOUTF_LL 2 21 1      0      0 SimLPL2        0.9996062717429675  -1.9082531975983987   0.9082707513809170  -1.9900610320883918   0.9900785927850526
ITMY_L2_COILOUTF_LL 5 21 1      0      0 AntiAcqOffL2     0.1111202139481815  -0.9954086141798147   0.0000000000000000  -0.9586809127066087   0.0000000000000000
ITMY_L2_COILOUTF_LL 6 21 1      0      0 AntiAcqOnL2    0.01702330742200748  -0.9994824154540793   0.0000000000000000  -0.9695955355155262   0.0000000000000000
ITMY_L2_COILOUTF_LL 7 21 1      0      0 AntiLPL2        1.000393883340034  -1.9900610320883918   0.9900785927850526  -1.9082531975983987   0.9082707513809170
################################################################################

jeffrey.garcia@LIGO.ORG - 15:25, Tuesday 04 September 2012 (4077)
For each of the four L1 (UIM) stage Coil Output Filter banks, the differences in the Foton text file are as follows:

Previously (before 08/31/2012):

################################################################################
### ITMY_L1_COILOUTF_LL                                                      ###
################################################################################
# DESIGN   ITMY_L1_COILOUTF_LL 0 zpk([],[],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 1 zpk([9.99999],[1],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 2 zpk([9.99999],[1],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 3 zpk([9.99999],[1],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 5 zpk([324.58],[59.9974],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 6 zpk([1],[9.99999],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 7 zpk([1],[9.99999],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 8 zpk([1],[9.99999],1,"n")
###                                                                          ###
ITMY_L1_COILOUTF_LL 0 21 1      0      0 Unknown                         1   0.0000000000000000   0.0000000000000000   0.0000000000000000   0.0000000000000000
ITMY_L1_COILOUTF_LL 1 21 1      0      0 SimLP1L1       0.1001725184293824  -0.9996165783185160   0.0000000000000000  -0.9961723865238130   0.0000000000000000
ITMY_L1_COILOUTF_LL 2 21 1      0      0 SimLP2L1       0.1001725184293824  -0.9996165783185160   0.0000000000000000  -0.9961723865238130   0.0000000000000000
ITMY_L1_COILOUTF_LL 3 21 1      0      0 SimLP2L1       0.1001725184293824  -0.9996165783185160   0.0000000000000000  -0.9961723865238130   0.0000000000000000
ITMY_L1_COILOUTF_LL 5 21 1      0      0 AntiAcqL1      0.1938898668876849  -0.9772519830087036   0.0000000000000000  -0.8826755757975039   0.0000000000000000
ITMY_L1_COILOUTF_LL 6 21 1      0      0 AntiLP1L1       9.982777868412679  -0.9961723865238130   0.0000000000000000  -0.9996165783185160   0.0000000000000000
ITMY_L1_COILOUTF_LL 7 21 1      0      0 AntiLP2L1       9.982777868412679  -0.9961723865238130   0.0000000000000000  -0.9996165783185160   0.0000000000000000
ITMY_L1_COILOUTF_LL 8 21 1      0      0 AntiLP2L1       9.982777868412679  -0.9961723865238130   0.0000000000000000  -0.9996165783185160   0.0000000000000000

################################################################################



Currently (as of 09/04/2012):

################################################################################
### ITMY_L1_COILOUTF_LL                                                      ###
################################################################################
# DESIGN   ITMY_L1_COILOUTF_LL 0 zpk([],[],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 1 zpk([10.5],[1],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 2 zpk([10.5],[1],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 3 zpk([10.5],[1],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 5 zpk([300],[50],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 6 zpk([1],[10.5],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 7 zpk([1],[10.5],1,"n")
# DESIGN   ITMY_L1_COILOUTF_LL 8 zpk([1],[10.5],1,"n")
###                                                                          ###
ITMY_L1_COILOUTF_LL 0 21 1      0      0 Unknown                         1   0.0000000000000000   0.0000000000000000   0.0000000000000000   0.0000000000000000
ITMY_L1_COILOUTF_LL 1 21 1      0      0 SimLP1L1      0.09541142041015412  -0.9996165783185160   0.0000000000000000  -0.9959813858777531   0.0000000000000000
ITMY_L1_COILOUTF_LL 2 21 1      0      0 SimLP2L1      0.09541142041015412  -0.9996165783185160   0.0000000000000000  -0.9959813858777531   0.0000000000000000
ITMY_L1_COILOUTF_LL 3 21 1      0      0 SimLP2L1      0.09541142041015412  -0.9996165783185160   0.0000000000000000  -0.9959813858777531   0.0000000000000000
ITMY_L1_COILOUTF_LL 5 21 1      0      0 AntiAcqL1      0.1744034418878165  -0.9810067536768792   0.0000000000000000  -0.8910959203698616   0.0000000000000000
ITMY_L1_COILOUTF_LL 6 21 1      0      0 AntiLP1L1       10.48092561352933  -0.9959813858777531   0.0000000000000000  -0.9996165783185160   0.0000000000000000
ITMY_L1_COILOUTF_LL 7 21 1      0      0 AntiLP2L1       10.48092561352933  -0.9959813858777531   0.0000000000000000  -0.9996165783185160   0.0000000000000000
ITMY_L1_COILOUTF_LL 8 21 1      0      0 AntiLP2L1       10.48092561352933  -0.9959813858777531   0.0000000000000000  -0.9996165783185160   0.0000000000000000
################################################################################
jeffrey.kissel@LIGO.ORG - 09:48, Wednesday 05 September 2012 (4087)
Looks good; thanks Garcia!
jeffrey.garcia@LIGO.ORG - 12:47, Wednesday 05 September 2012 (4092)
The ITMY & ETMY M0&R0 top stage CoilOutF filter modules matched the State Machine Diagram for the TOP Coil Driver before making modifications on the lower stage filter modules.

All filter modules for every ITMY,ETMY M0&R0 CoilOutF filter modules are identical and contain the following digital filters:

################################################################################
### ITMY_M0_COILOUTF_F1                                                      ###
################################################################################
# DESIGN   ITMY_M0_COILOUTF_F1 1 zpk([10],[1],1,"n")
# DESIGN   ITMY_M0_COILOUTF_F1 5 zpk([0.9],[31],1,"n")
# DESIGN   ITMY_M0_COILOUTF_F1 6 zpk([1],[10],1,"n")
###                                                                          ###
ITMY_M0_COILOUTF_F1 1 21 1      0      0 SimLPM0        0.1001724184483297  -0.9996165783185160   0.0000000000000000  -0.9961723827035119   0.0000000000000000
ITMY_M0_COILOUTF_F1 5 21 1      0      0 AntiAcqM0       34.24722014515512  -0.9881817593982465   0.0000000000000000  -0.9996549138717927   0.0000000000000000
ITMY_M0_COILOUTF_F1 6 21 1      0      0 AntiLPM0         9.98278783211981  -0.9961723827035119   0.0000000000000000  -0.9996165783185160   0.0000000000000000

################################################################################