Reports until 14:35, Tuesday 27 February 2018
H1 CDS
david.barker@LIGO.ORG - posted 14:35, Tuesday 27 February 2018 - last comment - 10:18, Thursday 01 March 2018(40746)
h1iscey glitched, we are negotiating recovery with EY install

h1iscey front end glitched at 14:15 PST. We are holding off on its restart until we contact EY group.

Comments related to this report
david.barker@LIGO.ORG - 14:48, Tuesday 27 February 2018 (40748)

killed and started all  models on h1iscey with EY permission.

keith.thorne@LIGO.ORG - 07:49, Wednesday 28 February 2018 (40763)CDS
I have seen glitches on my test stand H1-style ISCEX machine here at LLO (actually quite frequently).  It persists even with the GE FANUC RFM removed.  I have not tried it in an L1-style model mix yet.
betsy.weaver@LIGO.ORG - 10:18, Thursday 01 March 2018 (40788)

We believe this was physically due to brushing equipment past the cables which loop out of the front of the rack at the end station.  Note, these racks are in the middle receiving bay so frequently see traffic traverse in and out of the VEA.