thomas.shaffer@LIGO.ORG - posted 17:10, Thursday 01 March 2018 - last comment - 23:15, Thursday 01 March 2018(40795)
HAM6 work update

A quick rundown of today's activities in HAM6:

Pictures to come tomorrow.

Comments related to this report
sheila.dwyer@LIGO.ORG - 23:15, Thursday 01 March 2018 (40798)SQZ, SUS

Some additional notes about our work in HAM6 today:

We checked that the optical fibers are plugged in such that fiber SN6 is currently connected to the green input collimator, while SN7 is currently connected to the IR collimator.

We measured the open light values, and updated the gains (30000/open_light) and offsets (-open_light/2) in the OSEMINF filterbanks.

H1:SUS-ZM1_M1_OSEMINF_UL_INMON 31032.9073568
H1:SUS-ZM1_M1_OSEMINF_LL_INMON 21726.2587891
H1:SUS-ZM1_M1_OSEMINF_UR_INMON 29461.2057943
H1:SUS-ZM1_M1_OSEMINF_LR_INMON 30892.4419271

We also copied over the calibration into urad from ZM1, and engaged it.  

TJ noted that the serial number of the BOSEMs on ZM1 are:

UL: 585 UR:562 LL:446 LR:263