SEI Ground Siesmometer Mass Position Check (FAMIS #6096)
   Ran SEI seismometer mass position checks. The following are out of range:


There are 13 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 1 DOF X/U = -0.345 [V]
ETMX T240 1 DOF Z/W = -0.578 [V]
ETMX T240 2 DOF X/U = -0.491 [V]
ETMX T240 2 DOF Z/W = -1.077 [V]
ETMY T240 1 DOF Z/W = -1.013 [V]
ETMY T240 2 DOF Y/V = -0.852 [V]
ETMY T240 3 DOF X/U = -0.912 [V]
ETMY T240 3 DOF Y/V = -0.392 [V]
ITMX T240 1 DOF X/U = -0.594 [V]
ITMX T240 2 DOF Z/W = 0.343 [V]
ITMX T240 3 DOF X/U = -0.671 [V]
ITMY T240 3 DOF X/U = -0.677 [V]
ITMY T240 3 DOF Z/W = -1.293 [V]

and 

There are 2 STS proof masses out of range ( > 2.0 [V] )!
STS A DOF Y/V = -4.67 [V]
STS A DOF Z/W = 5.894 [V]

   All other T240s and STSs are reporting in range. 



Images attached to this report